Xenotime-(Y) CL spectrum, 20 keV e- beam, Rahman et al. 2020
Measurement details
Description | CL spectrum of Xenotime-(Y) from Cox's Bazar, Bangladesh |
Reference | Rahman et al. 2020 Rahman M. A., Tardio J., Bhargava S., Zaman M. N., Mehedi Hasan A. S. M., Torpy A. & Pownceby M. (2020). Comparison of the chemistry and mineralogy of ilmenite concentrates sourced from fluvial (Brahmaputra River) and beach placer (Cox's Bazar) deposits, Bangladesh., 117, 1-10. DOI: https://doi.org/10.1016/j.oregeorev.2019.103271 |
Date measured | 2015-03-03 |
Material | Xenotime-(Y) [ YPO4 ] |
Specimen | CB Monazite con [CSIRO], Cox's Bazar District, Chattogram Division, Bangladesh |
Technique | Cathodoluminescence (CL) |
Instrument | JEOL 8500F |
Probe | 20 keV electron beam |
Beam current | 59.37 nA |
Probe diameter | 2 μm |
Detector name | QE65000 |
Acquisition time | 29.8502 s |
Channel count | 1024 |
Wavelength range | 198.073 … 981.814 nm |
Intensity range | -1788.16 … 1.2707×106 counts |
Integral | 5.9425×107 counts |
Composition
Element | Atoms | At% | Wt% |
---|---|---|---|
Y | 1 | 16.7 | 48.4 |
P | 1 | 16.7 | 16.8 |
O | 4 | 66.7 | 34.8 |
Measurement spectrum