Cerium fluoride CL/SEM spectrum, e- beam, CSIRO 2017
Measurement details
Description | CL/SEM spectrum of Cerium fluoride |
Reference | Otherwise unpublished luminescence spectra measured by the CSIRO Mineral Resources Microbeam Laboratory, Clayton https://research.csiro.au/microbeam-lab/ |
Material | Cerium fluoride [ CeF3 ] |
Specimen | CeF3 RE-3 [CSIRO - Microbeam Lab standard blocks] |
Technique | Cathodoluminescence (CL), using an Electron Probe Micro-Analyser (EPMA) |
Instrument | JEOL 8500F |
Probe | Electron beam |
Channel count | 1024 |
Wavelength range | 199.946 … 976.403 nm |
Intensity range | 0.053335 … 153.759 counts |
Integral | 9141.44 counts |
Lines | Ce 2.75 — 4.65 eV, 4.1079 eV (100%) |
Composition
Element | Atoms | At% | Wt% |
---|---|---|---|
Ce | 1 | 25 | 71.1 |
F | 3 | 75 | 28.9 |
Measurement spectrum
Loading...
Measurement image
OpticalFit peak fitting of CeF3 cathodoluminescence spectrum
© CSIRO Mineral Resources